Flangeolet | Flanged Branch Outlet | MSS SP-97 | RF / FF / RTJ | Class 150–2500
Elite provides Flangeolets for compact, integrally reinforced branch connections in process piping systems. A Flangeolet combines a forged branch outlet with a flanged connection, providing a direct 90° branch from a main pipe or header to valves, equipment or branch piping.
The flanged outlet eliminates the need for a separate branch fitting and flange assembly, providing a compact connection suitable for process headers, high-pressure piping and equipment connections. Flange dimensions and facing are selected according to the applicable flange standard and project requirements.
| Specification | Details |
|---|---|
| Product Type | Flangeolet / Flanged Branch Outlet |
| Branch Outlet Standard | MSS SP-97, where applicable |
| Flange Dimension Standard | ASME B16.5, where applicable |
| Large Diameter | ASME B16.47, where applicable |
| Pipeline Applications | MSS SP-44, where applicable |
| Nominal Flange Size | NPS 1/2–24 under ASME B16.5; larger sizes available to project requirements |
| Pressure Classes | 150, 300, 400, 600, 900, 1500, 2500 |
| Branch Configuration | 90° flanged branch outlet |
| Facing | RF, FF or RTJ, where applicable |
| Construction | Forged and machined |
| Branch Bore | Standard or project specific |
| Branch Connection | Butt-weld / pipe branch connection |
| Flange Connection | Bolted flanged outlet |
| Dimensions | Standard or project specific |
| Heat Treatment | As required by material specification |
| Surface Finish | Standard or customer specified |
| Marking | Size, class, material, heat number and required identification |
| Inspection | Visual, dimensional, material and mechanical testing as applicable |
| NDE | PMI, UT, MT, PT and other methods as specified |
| Documentation | MTC, EN 10204 3.1/3.2, COC and inspection reports |
| Custom Requirement | Details |
|---|---|
| Main Pipe Size | NPS or project-specific diameter |
| Branch Size | NPS or project-specific diameter |
| Pressure Class | 150–2500 or project specified |
| Material | Required material grade |
| Flange Facing | RF / FF / RTJ, where applicable |
| Flange OD | Standard or project specified |
| Flange Thickness | As required |
| Branch Bore | Project specific |
| Branch Wall Thickness | Based on design requirements |
| Bolt Circle | As required |
| Bolt Holes | Number, diameter and configuration |
| Overall Dimensions | Project specific |
| NDE | Project specified |
| Inspection | ITP / third-party requirements |
| Marking | Customer requirements |
| Inspection / Documentation | Availability |
|---|---|
| Material Test Certificate | Available |
| EN 10204 3.1 | Available |
| EN 10204 3.2 | Where specified |
| Certificate of Conformance | Available |
| Dimensional Inspection | Available |
| Chemical Analysis | Material dependent |
| Mechanical Testing | Material dependent |
| Heat Treatment Records | Where applicable |
| PMI | As specified |
| Ultrasonic Testing (UT) | As specified |
| Magnetic Particle Testing (MT) | As specified |
| Liquid Penetrant Testing (PT) | As specified |
| Visual Inspection | Standard |
| Third-Party Inspection | Available |
| ITP | Project specific |
| Material Traceability | Maintained |
| Packing & Marking Records | Available |
Note: Flangeolets are specialized forged branch outlet fittings. MSS SP-97 is the principal standard for the integrally reinforced branch outlet, while the flange portion may follow ASME B16.5 or another applicable project standard.
Carbon Steel
ASTM A105/A105N, ASTM A181, ASTM A350 LF2/LF3 and ASTM A694 F42, F46, F52, F60 and F65.
Stainless Steel
ASTM A182 F304/F304L, F316/F316L, F321/F321H, F347/F347H, F310/F310S, F317 and F904L.
Duplex & Super Duplex
ASTM A182 F51, F53 and F55.
Alloy Steel
ASTM A182 F1, F5, F9, F11, F12, F22, F91 and F92.
Nickel Alloys
Nickel 200/201, Monel 400/K500, Inconel 600/601/625/800/825, Hastelloy C276 and Alloy 20.
Copper-Nickel Alloys
UNS C70600 and C71500, including 90/10 and 70/30 Cu-Ni alloys.
Material selection is based on operating pressure, temperature, process fluid, corrosion conditions, mechanical requirements and applicable project specifications.
90° Flanged Branch Outlet
A Flangeolet provides a 90° branch from the main pipe or header with an integral flanged outlet. The flange allows direct bolted connection to valves, piping, equipment or other flanged components.
Integrally Forged Construction
The branch outlet is manufactured as an integrated forged component, providing a compact connection and eliminating the need for a separate fabricated branch and flange assembly.
Reinforced Branch Design
The branch outlet incorporates an integrally reinforced body designed according to the applicable branch fitting standard, pipe dimensions, pressure, temperature and service requirements.
Flange Facing
Available configurations include:
Facing selection depends on size, pressure class, mating equipment and project requirements.
Elite’s manufacturing and inspection process can include:
Flangeolets are commonly used in:
For quotation, provide:
Main Pipe Size + Branch Size + Pressure Class + Material + Facing + Flange Standard + Branch Configuration + Quantity + Inspection Requirements
Example
8″ × 4″ Class 600 Flangeolet, ASTM A105N, RF, MSS SP-97, ASME B16.5 flange dimensions, forged construction, EN 10204 3.1.